Specifications — MHRVGA Cable
UL NEC/
C(UL) CEC
UL AWM
Temp.
Standard
Lengths Weights
Shipping Conductor
Nominal
Core OD
Shielding
Materials
(% coverage)
Nom. DCR
Nominal
OD
Nominal
Capacitance
Nominal
Attenuation
Description
Nom.
Vel.
of
No.
of
Cond.
Nom.
Imp.
(ohms)
(stranding)
Diameter
Nom. DCR
Part No. (length)
Model
dB/
dB/
MHz
Prop.
Ft.
m
Lbs. kg
Inch mm
Inch mm
pF/ft pF/m
100 ft 100 m
Composite Cable: (3) 26 AWG Miniature Coax • (2) 26 AWG Shielded Twisted Pairs • (7) 26 AWG Insulated Conductors
Overall Cable Shield: Aluminum Foil (100%) + Tinned Copper Braid
Nonplenum Cable • Natural Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
1
5
10
20
50
-0.5
-1.2
-1.7
-2.4
-3.8
-4.5
-5.4
-6.3
-7.3
-7.7
-9.1
-11.5
-16.4
-19.5
-43.6
-1.7
-3.9
-5.5
26 AWG
(7/34)
0.019"
Alum. Foil
(100%)
3
coax
0.076 1.93
75
83%
18.0
59.1
500 152.4 54 24.5
304.8
Single:
0.105 2.67
red, green, blue
22-024-01 (500')
22-024-03 (1000')
1000
95 43.1
Tinned Cu
Serve (95%)
-7.8
MHRVGA
0.48 mm,
-12.3
-14.8
-17.6
-20.6
-23.9
-25.4
-29.9
-37.3
-53.8
-64.0
-143.0
Tinned Cu
12.2 ohms/
1k ft,
40.0 ohms/
1 km
71
100
135
180
200
270
400
750
1000
3000
41 ohms/
1k ft,
135 ohms
1 km
Sweep tested 5 MHz to 1 GHz.
66% 35 115
Same as
above
Tinned Cu
Braid (85%)
Single:
black & red
black & white
2
0.033 0.84
NEC CM
UL 1581
CSA FT-4
AWM 2990
VW-1
shielded
twisted
pairs
conductor-
conductor
62
203
conductor-
conductor,
connected to
shield
Min. bend radius: 4.0"
60 °C
Same as
above
Single:
blue, green,
violet, grey,
yellow, orange,
brown
7
0.033 0.84
insulated
conduct-
ors
Alum. Foil and
Tinned Cu
Braid (85%)
Overall:
Overall
cable
0.330 8.39
gray
Plenum Cable • Natural Foamed FEP Insulation • PVC Inner Jackets • Blue Fire-Resistant PVC Outer Jacket
58
1
5
10
20
50
-0.5
-1.1
-1.6
-2.3
-3.6
-4.3
-5.1
-6.0
-7.0
-7.4
-8.8
-11.8
-17.6
-21.4
-51.2
-1.5
-3.7
-5.4
152.4
26 AWG
(7/34)
0.019"
Alum. Foil
(100%)
500
26.3
3
coax
0.074 1.88
75
81%
16.7
54.8
Single:
0.102 2.60
red, green, blue
22-131-02 (500')
22-131-03 (1000')
1000 304.8 99 44.9
Tinned Cu
Serve (95%)
-7.5
MHRVGAP
0.48 mm,
-11.8
-14.1
-16.8
-19.7
-23.0
-24.3
-28.8
-38.7
-57.8
-70.1
-168.0
Tinned Cu
12.2 ohms/
1k ft,
40.0 ohms/
1 km
71
100
135
180
200
270
400
750
1000
3000
41 ohms/
1k ft,
135 ohms
1 km
Sweep tested 5 MHz to 1 GHz.
66% 35 115
Same as
above
Tinned Cu
Braid (85%)
Single:
black & red
black & white
2
0.033 0.84
shielded
twisted
pairs
conductor-
conductor
NEC CMP
UL 910
75 °C
62
203
conductor-
conductor,
connected to
shield
Min. bend radius: 6.0"
Same as
above
Single:
blue, green,
violet, grey,
yellow, orange,
brown
7
0.033 0.84
insulated
conduct-
ors
Alum. Foil and
Tinned Cu
Braid (85%)
Overall:
Overall
cable
0.330 8.38
blue
02 December, 2008
|
Eton Weather Radio G1000A User Manual
Excalibur electronic Games EI PT1001 User Manual
FEIN Power Tools Grinder WSG 20 180 User Manual
Fujitsu Laptop SPFC T901 DGFX 1 User Manual
Fujitsu Scanner iX500 User Manual
GBC Paper Shredder 3550X User Manual
GE Clothes Dryer 234D1050P001 User Manual
GE Cooktop AHH50 User Manual
GE Home Security System 45136 User Manual
GE Washer WWA8657R User Manual